Optimal smoke tube arrangement and burner with high combustion efficiency deliver high boiler efficiency.
Applying direct (closed) condensate water recovery system makes it possible to recover almost 100% of the condensate water energy.
As one of characteristics of Fire (smoke) tube boiler, large amount of boiler water can stably supply steam with little pressure fluctuation even under fluctuating steam load.
Energy saving and stable steam supply


Lower environmental impact
Low NOx oil burner / Dual fuel fired burner
The oil fired burner uses two-stage combustion type steam atomizing burner (KTC burner) to minimize NOx emissions and to support heavy oil.
The dual fuel fired burner is not needed to be replaced when switching fuel. It can be easily switched between gas and oil by changeover switch on control panel and linkage.



KTC burner (oil fired burner)
Specification
KS series | |
---|---|
Actual evaporation | 1,000 to 12,000 kg/h |
Maximum working pressure | 0.98 to 1.56 MPa |
Boiler efficiency | 88 to 92% |
Fuel | Natural gas, LPG, Hydrogen, kerosene, Diesel Oil |